The Consilium / Salwico NS-CP (N1305 GB) is a conventional manual fire alarm call point (MCP) designed for marine fire alarm systems. The GB version uses break-glass activation, where pressing/cracking the protected glass operates the alarm circuit; the N1305 version is intended for harsh/wet environments with IP55 protection.
Key Features
- Manual fire alarm activation by pressing the protected glass.
- IP55 enclosure suitable for harsh and damp marine environments.
- Protective plastic coating helps prevent injury from broken glass.
- Built-in test facility using the supplied test key.
- Robust PC/ABS housing.
- Conventional fire-alarm circuit connection with end-of-line supervision.
- Suitable for use in certain intrinsically safe areas when used with the appropriate NS isolator, according to the product documentation.
- The N1305 series was subsequently replaced in Consilium’s product range by the MCP-C IP67 GB (5200014-01A) for wet-space applications.
Typical Applications
- Shipboard manual fire alarm stations.
- Engine rooms and machinery spaces.
- Damp or exposed technical areas.
- Offshore installations.
- Cargo and service areas.
- Conventional Salwico fire alarm systems such as C300/C303/C308/C316 and compatible marine systems.