Salwico Consilium ES-2K (46460)

Zener Barrier Isolator

  • Maker : Salwico Consilium
  • Model : ES-2K
  • Part No : 46460
  • Description : Zener Barrier Isolator
  • Condition : Refurbished
  • Warranty : 6 months

To receive a quote for Salwico Consilium ES-2K (46460), email us : info@shipautomation.com

Have any Questions?

Feel free to Get in touch

Request A Free Quote





    Salwico Consilium ES-2K (46460) is a Zener barrier isolator used as part of an intrinsically safe interface for Salwico CS3000 and CS3004 fire alarm systems. It connects between the AE-2K/I address unit and the Zener barrier, allowing intrinsically safe fire-detection devices to be used in hazardous areas such as Zones 0, 1 and 2.

    Key Features

    • Zener barrier isolation for intrinsically safe fire-detection circuits
    • Designed for Salwico CS3000 and CS3004 fire alarm systems
    • Interfaces with the AE-2K/I address unit and Zener barrier
    • Supports intrinsically safe devices in hazardous areas
    • Suitable for manual call points, heat detectors and smoke detectors
    • Robust aluminium construction with IP56 protection
    • 24 VDC operation with 18–30 VDC allowable input range

    Typical Applications

    • Marine fire detection and alarm systems
    • Engine rooms and machinery spaces
    • Offshore and hazardous-area installations
    • Zone 0, Zone 1 and Zone 2 classified areas
    • Intrinsically safe smoke and heat detector circuits
    • Salwico CS3000 / CS3004 fire alarm installations
    Salwico Consilium ES-2K (46460) is a Zener barrier isolator used as part of an intrinsically safe interface for Salwico CS3000 and CS3004 fire alarm systems. It connects between the AE-2K/I address unit and the Zener barrier, allowing intrinsically safe fire-detection devices to be used in hazardous areas such as Zones 0, 1 and 2.

    Key Features

    • Zener barrier isolation for intrinsically safe fire-detection circuits
    • Designed for Salwico CS3000 and CS3004 fire alarm systems
    • Interfaces with the AE-2K/I address unit and Zener barrier
    • Supports intrinsically safe devices in hazardous areas
    • Suitable for manual call points, heat detectors and smoke detectors
    • Robust aluminium construction with IP56 protection
    • 24 VDC operation with 18–30 VDC allowable input range

    Typical Applications

    • Marine fire detection and alarm systems
    • Engine rooms and machinery spaces
    • Offshore and hazardous-area installations
    • Zone 0, Zone 1 and Zone 2 classified areas
    • Intrinsically safe smoke and heat detector circuits
    • Salwico CS3000 / CS3004 fire alarm installations
    SpecificationDetails
    ManufacturerConsilium / Salwico
    ModelES-2K
    Part No.46460
    Product TypeZener Barrier Isolator / Intrinsically Safe Interface
    Compatible SystemsSalwico CS3000, CS3004
    Power Input24 VDC (18–30 VDC)
    Operating CurrentApprox. 15–65 mA (idle/max)
    Cable DiameterØ7–13 mm
    Cable Terminals1.5 mm²
    Ingress ProtectionIP56
    MaterialAluminium
    ColourWhite
    WeightApprox. 585 g

    Net Weight (kg):