Consilium GSK-2 (042190)

Interface Board

  • Maker : Consilium
  • Model : GSK-2
  • Part No : 042190
  • Description : Interface Board
  • Condition : Refurbished
  • Warranty : 6 months

To receive a quote for Consilium GSK-2 (042190), email us : info@shipautomation.com

Have any Questions?

Feel free to Get in touch

Request A Free Quote





    The Consilium GSK-2 (042190) is an interface board used in the Salwico CS3000 fire alarm system. It provides the interface for connecting conventional digital detector sections to the central fire alarm system and communicates alarm, fault, and status information to the central unit.

    Features

    • Four-section interface for conventional digital detectors.
    • Designed for integration with the Salwico CS3000 fire alarm system.
    • Collects fire alarm, fault, and status information.
    • Uses IDA circuits for communication with the central unit.
    • Individual electrical isolation of detector sections.
    • Built-in transient and high-frequency interference protection.
    • Local 5 V DC and 12 V DC voltage regulation.
    • LED indication for internal power status.
    • Binary switch configuration for board addressing.
    • Front-accessible fuse for protection and power disconnection.
    • Modular PCB construction for installation in the CS3000 rack.’

    Typical Applications

    • Marine fire detection systems
    • Salwico CS3000 fire alarm systems
    • Conventional detector section interfacing
    • Shipboard central fire alarm panels
    • Fire and fault signal monitoring
    • Conventional digital detector integration
    • Cargo and commercial vessels
    • Passenger vessels
    • Engine rooms and machinery spaces
    • Offshore and marine installations
    • Retrofit of conventional detection circuits
    • Replacement of existing GSK-2 interface boards
    The Consilium GSK-2 (042190) is an interface board used in the Salwico CS3000 fire alarm system. It provides the interface for connecting conventional digital detector sections to the central fire alarm system and communicates alarm, fault, and status information to the central unit.

    Features

    • Four-section interface for conventional digital detectors.
    • Designed for integration with the Salwico CS3000 fire alarm system.
    • Collects fire alarm, fault, and status information.
    • Uses IDA circuits for communication with the central unit.
    • Individual electrical isolation of detector sections.
    • Built-in transient and high-frequency interference protection.
    • Local 5 V DC and 12 V DC voltage regulation.
    • LED indication for internal power status.
    • Binary switch configuration for board addressing.
    • Front-accessible fuse for protection and power disconnection.
    • Modular PCB construction for installation in the CS3000 rack.’

    Typical Applications

    • Marine fire detection systems
    • Salwico CS3000 fire alarm systems
    • Conventional detector section interfacing
    • Shipboard central fire alarm panels
    • Fire and fault signal monitoring
    • Conventional digital detector integration
    • Cargo and commercial vessels
    • Passenger vessels
    • Engine rooms and machinery spaces
    • Offshore and marine installations
    • Retrofit of conventional detection circuits
    • Replacement of existing GSK-2 interface boards

    Key Specifications

    SpecificationDetails
    Manufacturer / BrandConsilium Salwico
    ModelGSK-2
    Part Number42190 / 042190
    Product TypeInterface Board / PCB Module
    Compatible SystemSalwico CS3000
    Primary FunctionInterface for conventional digital detector sections
    Number of Sections4 sections
    Section AddressingFirst section address set manually; remaining 3 receive consecutive addresses
    CommunicationIDA communication circuits
    Signal HandlingFire alarm, fault and status information
    Section IsolationEach section can be electrically isolated by double relay
    Input ProtectionProtection against transients and high-frequency interference
    Internal Logic Supply5 V DC
    Additional Internal Supply12 V DC
    Nominal Input CurrentApprox. 25 mA at 24 V DC
    Maximum Input CurrentApprox. 25 mA at 24 V DC
    Fuse Rating2 AT, 5 × 20 mm
    Address SettingBinary address switch
    InstallationCS3000 central-unit rack / CSR-3200
    Associated BoardSPK-2 loop processor board when used for conventional digital detector sections

    Net Weight (kg):

    Dimension (cm):